By style

The six we fit.

Casement

Cranks outward. Seals tightest of any operating window.

Read the spec →

Slider

Slides sideways in a track. Nothing swings out over a walkway.

Read the spec →

Picture

Glass straight into the frame. Most glass, best performance.

Read the spec →

Awning

Hinged at the top. Can stay open in rain.

Read the spec →

Tilt & turn

Two ways to open from one handle. European hardware.

Read the spec →

Bay & bow

Projects outward. Adds floor area and light from three sides.

Read the spec →

Options

What goes into every unit.

Locking system

The lock is not only security — on an operating window it is what pulls the sash tight against the weatherstrip. A loose or badly adjusted lock is the most common cause of a draft that gets blamed on the window itself.

  • Multi-point locking available on casement and awning, engaging the sash at several points along the frame rather than one
  • Single-point cam locks on sliders and hung units
  • Hardware rated for repeated operation at low temperature — the failure mode here is stiffening, not breakage
  • Keyed options where a ground-floor opening needs it

Glass and glazing

We fit both double and triple pane, and you choose. Triple-pane, argon-filled and Low-E is what we recommend in Edmonton, because the outside face sits at −30 °C for weeks — and it is what CEIP financing requires here. Double-pane is a sound choice on a sheltered elevation or a tighter budget, and we will say so rather than talk you out of it.

  • Double or triple pane, argon-filled — triple recommended for this climate
  • Low-E coating to reduce radiant heat loss
  • Warm-edge spacer between panes, which is where cheap units give away their performance
  • Tempered or laminated where code requires it — near doors, in bathrooms, below a certain sill height
  • Obscure and patterned glass available for bathrooms

Frame, jamb and trim

The jamb depth has to match your wall. Getting this wrong is what produces the ugly filler strip you see on cheap replacement jobs, so we measure the actual wall rather than assuming a standard.

  • Jamb depth measured to your wall assembly, not assumed
  • Jamb extensions where the wall is deeper than the standard frame
  • Brickmould exterior trim, which covers the joint between frame and cladding and sheds water away from it
  • Interior casing to match or replace existing trim
  • Nailing fin or brickmould installation depending on whether the cladding is being disturbed

Sizes

Every unit is made to the measured opening. There is no standard size we try to make fit, which matters on Edmonton houses from the 1980s and 90s where openings are rarely exactly what the plans said.

  • Manufactured to the measured opening, not to a stock size
  • Combination units — a fixed picture flanked by operating casements, for example — built as one assembly
  • Egress-compliant sizing where a basement bedroom requires it: minimum 0.35 m² clear opening, no dimension under 380 mm

Screens

Supplied with every operating unit. Fixed units do not get one because there is nothing to screen.

  • Standard fibreglass mesh on all operating units
  • Heavier pet-resistant mesh available
  • Full screens on casement and awning, half screens on sliders and hung units
  • Removable from inside for cleaning

Colours and finish

White is the base. Exterior colours cost more from the manufacturer, and the exterior and interior do not have to match — a black exterior with a white interior is a common and sensible combination.

  • White as standard, inside and out
  • Exterior colours including black and bronze, at additional cost
  • Different interior and exterior finish available on the same unit
  • Grilles and grids available in several patterns where the house calls for them

What we specify

Why we recommend triple-pane here.

Windows and doors are up to 25% of a home's heat loss. In a climate that runs −25 to −35 °C for weeks, the third pane pays for itself in comfort before it pays for itself on the bill — the inside face of the glass simply stays warmer, so you stop feeling the cold draft that is not actually a draft.

Glazing
Double or triple pane, argon-filled
Coating
Low-E
ENERGY STAR threshold
U ≤ 0.21 · ER ≥ 34
Standard compliance
NAFS / CSA A440
Triple over double
Recommended here; required for CEIP
A living room with floor-to-ceiling black-framed glazing at golden hour.

One case needs its own page

Basement bedrooms need an egress window.

If a basement room is used as a bedroom, the Alberta Building Code requires a window a person can get out of — minimum 0.35 m² clear opening, no dimension under 380 mm, openable from inside without tools. Cutting the foundation to make one needs a City of Edmonton permit.

Egress windows explained

Common questions

Is triple-pane worth it in Edmonton?

For most Edmonton homes, yes — it runs −25 to −35 °C for weeks at a time, and triple-pane is also what CEIP financing requires here. We fit both, so it is your call: on a sheltered elevation or a tighter budget, double-pane is a sound choice and we will say so.

What is an ER rating?

Energy Rating is a single Canadian number combining U-factor, solar heat gain and air leakage. ENERGY STAR certification requires ER of at least 34 and a U-factor no higher than 0.21.

Do I need a permit to replace a window?

Not for a like-for-like replacement in an existing opening. You do need a City of Edmonton building permit if the opening is being enlarged or the foundation cut, which is common for basement egress.

Can you install in winter?

Yes, down to about −20 °C, using cold-weather foams and sealants and working one opening at a time so the house is never open. Vinyl does get more brittle in deep cold, which slows cutting.

Know what a quote covers, and what it does not.